CASE STUDIES

AISUS Completes Caisson Inspection and Cleaning in the North Sea

Case study

Rig with yellow stairs

Background

AISUS was tasked by a client in the Norwegian North Sea to carry out a Remote Ultrasonic Inspection on a caisson which had severed.

Experienced and competent engineers were deployed to complete an internal ultrasonic inspection on a seawater lift caisson.

The client’s asset had failed and a section of the caisson had detached at a weld within an external guide support and fallen to the seabed. The remaining length was insufficient to cover the length of the pump string, with pump exposed below. Adoption of external ROV and crawler inspection methods previously had not identified the degradation mechanism which caused the failure. Through regular internal inspection this failure could have been prevented, by identifying the failure mechanism early inside the guide support and allowing the client to put suitable mitigation in place.

The Inspection

On a typical caisson scope of work, AISUS would normally complete the visual inspection along with high pressure cleaning prior to ultrasonic inspection. On this occasion, the operator completed these services with another vendor prior to our arrival. In order to avoid any loss of key information in the inspection process, the visual inspection results were requested prior to AISUS mobilising to the platform.

Followed by the cleaning and visual inspection, AISUS was tasked to carry out an internal ultrasonic inspection to collect the wall thickness data by deploying SIRIUS, an in-house designed and manufactured ultrasonic inspection tool. The scope was required to highlight any other sections of the caisson that were showing signs of deterioration which may have required further attention during a planned repair project.

Benefits

This inspection helped the client to understand the condition of the remaining caisson in order to bring the caisson back into service through the installation of a swaged repair. Internal inspection also identified defects caused by the interaction between the caisson and pump string which would have not been identified using other inspection methods. Identification of these defects allowed the repair scope to be adjusted, extending the length of the swage repair, and ensured unnecessary future risks and costs were mitigated.

The client was delighted with the results of the inspection which gave them comprehensive data on the condition of the remaining caisson prior to the installation of a swaged repair.

Recent Case Studies

Custom Solution: Remote PIG Retrieval

Overview A Middle Eastern client approached AISUS with an urgent operational challenge on a Well Head Platform in Qatar. A PIG had become lodged approximately 7 metres beyond the PIG launcher, within the first isolation value of a 38″ wet gas line, leaving no established method for safe retrieval. Recognising the critical nature of the […]

Project c|Ai|sson: Predicting Future Caisson Integrity Through AI-Driven Forecasting

Overview For more than a decade, AISUS has deployed remote robotic inspection technologies across offshore assets worldwide, providing operators with safe and cost-effective access to critical infrastructure. Through thousands of inspections, AISUS has built an extensive dataset on the condition and degradation of offshore caissons, many of which continue to operate beyond their original design […]

Internal cleaning & UT Inspection of North Sea Conductors

Overview AISUS were commissioned by a North Sea operator to undertake a comprehensive internal cleaning and inspection campaign on ten conductors ranging from 20″ to 30″ in diameter. The work formed a critical part of a large-scale decommissioning project and was completed in advance of a planned cut-and-pin operation. The primary objective was to provide […]
ENQUIRE NOW